LUN-25 2G/3G
Lun-25 - intrusion and fire alarm control panel that is designed for installation in residential houses, small offices and ATMs. The main application is the protection of apartments.
Supports up to 30 wireless sensors and remote keyfobs. The device is concealed in a small and stylish housing along with the power supply unit and 2A/h 12V lead battery. The device is designed to operate through a 3G and Wi-Fi network (Wi-Fi is provided by a separate module), supports up to 2 SIM cards.
Lun-25 produced in 4 versions:
(available in 2G and 3G versions and in Lun-11 housing for 7 Ah batteries.)
- Lun-25 - the device without integrated control and display means, designed for use with Lind-9M3/Lind-15/Lind-EM/Lind-11TM/antivandal TM keys reader.
- Lun-25T - a device with integrated TM anti-vandal key reader and multi-functional LED built-in directly on the housing.
- Lun-25E - a device with integrated RFID EMMarine card reader and multi-functional LED built-in directly on the housing.
- Lun-25K - a device with integrated Lind-27 digital touch keyboard with additional LED indicators.
Specifications:
- 5 wired zones with the 2KOhm EOL resistor. Zone power management is present.
- Zone types: interior, 24-hour, delayed, entry/exit, arming, fire, arm stay, general alarm, Interior delayed/Instant, Arming by pulse;
- 2 groups.
- 2 programmable open collector outputs, switching current up to 120mA.
- Power supply output + 12V for sensors and external siren with resettable 500 mA fuse.
- Supported wireless systems: Visоniс, Cгоw, Jаblotron;
- Memory for 128 events
- Real-time clock.
Siren:
The panel has 1 open collector type output with switching current up to 200 mA (on request can be increased to 500 mA) to connect siren, included for all groups under the "OR" scheme. Siren output monitoring is not supported.
Keys and passwords:
- The total number of users – 32
- Users distributed between groups 16/16
Output Types:
- Siren (works for all "or" groups under the scheme)
- Group 1 External LED
- Group 2 External LED
- General alarm
- Group 1 Alarm
- Group 2 Alarm
- Fire Alarm
- Control from CMS (or Phoenix-MK)
Event buffer – 128 events, (non-volatile memory)
Lun-25 Installation Guide -
Lun-25_IG_rev_01_en.pdf (607.11 Kb)
updated: 2018-01-18 |
download |
Lun-25 (2G) Reference Manual -
Lun-25_RM_rev_26_en.pdf (2.68 Mb)
updated: 2021-06-22 |
download |
Lun-25 User Manual -
Lun-25_UM_rev_02_en.pdf (565.6 Kb)
updated: 2018-01-18 |
download |
Helpfile - Lun-25 working with lun.ortus.io -
Lun_25_web.pdf (626.85 Kb)
updated: 2018-03-29 |
download |
Helpfile - Configuring Lun-25 for lun.ortus.io -
Configuring Lun-25 for lun.ortus.io.pdf (874.21 Kb)
updated: 2018-03-29 |
download |
Helpfile - Remote configuration Lun-25 via lun.ortus.io -
rem_conf_Lun_25_web.pdf (187.69 Kb)
updated: 2018-03-29 |
download |
Lun-25mod.2 (3G) Reference Manual -
Lun-25mod.2_RM_rev_09_en.pdf (2.33 Mb)
updated: 2021-07-21 |
download |